6. Connect the unfused cable to the Negative (-) terminal of the battery bank.
7. Connect the Negative cable to the Inverter’s Negative (-) terminal.
8. Insulate the end of cable to be connected to the Pos (+) Inverter terminal.
9. Connect the fused cable to the battery bank Pos (+) terminal.
10. Connect the Pos cable end to the Pos (+) inverter terminal.
NOTE: Sparking is normal for the first connection.
Make sure you have good secure connections – Do not over-tighten.
Operation
1. Turn On (I) the inverter. Make certain the Over Load LED is not lit.
2. Turn OFF (0) the inverter. The Over Load LED may briefly "blink" and the
audible alarm may also sound a short "chirp." This is normal.
3. When you have confirmed that the appliance to be operated is turned off,
plug an appliance cord into one of the four 110v AC Outlets on the front
panel of the inverter.
4. Turn ON the inverter.
5. Turn the appliance on.
6. Plug in additional appliances and turn them on.
Notes:
The audible alarm may make a momentary "chirp" when the inverter is
turned OFF. This same alarm may also sound when the inverter is
being connected to or disconnected from the 24 volt battery bank.
When using an extension cord from the inverter to an appliance the
extension cord should not be longer than 50 feet.
Television and Audio Suggestions
Although all PowerBright
TM
inverters are shielded and filtered to minimize
signal interference, some interference with your television picture may be
unavoidable, especially in weak signal areas.
However, here are some suggestions that may improve reception:
1. First, make sure that the television antenna produces a clear signal under
normal operating conditions. Also, ensure that the antenna cable is properly
shielded and of good quality.
2. Change the positions of the inverter, antenna cables and TV power cord.
3. Isolate the TV, its power cord and antenna cables from the 24 volt power
source by running an extension cord from the inverter to the television set.
4. Coil the television power cord and the input cables running from the 24
volt power source to the inverter.